C280-16 Generator Set (Medium Speed)
Description
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Manufacturer: CAT
Brochures & Links
Specifications
Download Specification Sheets
| Maximum Rating | 4840 ekW (60Hz), 6500 kVA (50Hz) |
|---|---|
| Minimum Rating | 4400 ekW (60Hz), 5875 kVA (50Hz) |
| Emissions/Fuel Strategy | EPA Tier 4 Final, IMO Tier 2 |
| Frequency | 50 / 60 Hz |
| Speed | 900 / 1000 rpm |
| Duty Cycle | Prime, Continuous |
| Engine Model | C280-16, V-16,4-Stroke Water-Cooled Diesel |
|---|---|
| Bore | 11 in280 mm |
| Stroke | 11.8 in300 mm |
| Displacement | 18032 in³296 l |
| Compression Ratio | 13:01 |
| Aspiration | TA |
| Fuel System | Direct unit injection |
| Governor Type | Generator Set Monitoring System (GMS) |
| Length - Maximum | 404 in10261.7 mm |
|---|---|
| Width - Maximum | 99.62 in2530.3 mm |
| Height - Maximum | 156.6 in3977.7 mm |
| Dry Weight - Genset (maximum) | 141840 lb64470 kg |
Key Features
Cat® Diesel Engine
- Designed and optimized for Marine EPA Tier 4 or IMO Tier 2 emissions
- Reliable, rugged, durable design
Alternators
- Superior motor starting capability minimizes need for oversizing generator
- Matched to the performance and output characteristics of Cat engines
Generator Set Package
- Fully prototype tested with certified torsional vibration analysis available
Worldwide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Cat Generator Set Monitoring System (GSM)
- Simple user friendly interface and navigation
- Provides protection, monitoring, and control of the diesel generator set
- Redundant shutdown protection
- 10 inch (254 mm) color monitor to display all engine parameters and alarm annunciation
- Annunciation of all engine shutdowns, alarms, and status points
- Start/prelube control switch, fuel control switch and emergency stop buttons
- Speed control switch with automatic changing to ball head control when a governor failure occurs, if ball head control is available
- Contacts are available for customer use
- Selection of local/remote control of engine
- Selection of idle/rated control of engine
- Equipped for remote communication
- Four 4-20mA outputs (programmable)
- Relay contact signals to the remote monitoring system (summary shutdown, summary alarm, local operation/remote, engine running, PLC failure, fuel control and idle/rated)
Equipment
Standard Equipment
Air Inlet System <!-- 3600 series only -->
- Air inlet shutoff
- Turbocharger, watercooled, engine oil lubricated
- Breather, crankcase, top-mounted
- Aftercooler, fresh water, corrosion resistant coated (air side)
- Air cleaner
Cooling System
- Three-bundle oil cooler
- Jacket water thermostats
- Front Mounted turbos
- Engine coolant water drains
- Water temperature regulator
Exhaust System
- Dry, gas tight, exhaust manifold
- 457 mm (18 in) Cat bolt pattern
- Includes adapter, flexible exhaust fitting
Fuel System
- Simplex or duplex
Generator System
- Custom generator per generator data sheet completed by dealer
Governor System
- UG Actuator
Lube System
- Wet oil sump. Includes engine-driven main lubrication and oil pumps, oil lines and oil pan
- Centrifugal oil filters with single shutoff
- Oil filler and dipstick
- Service Side Engine mounted on Cylinder Block Inspection Covers
- Crankcase explosion relief valves
- Oil pressure regulating valve
Mounting System
- Damper, torsional vibration
- Engine and generator mounting
Starting / Charging System
- Line group for single point custom connection
- Two Motors, engine mounted at rear, on left side
- Vane type air starter
- Air silencer
General:
- Gear driven pumps: Fuel/oil/jacket water/Aftercooler/Oil cooler water
- Paint, Caterpillar yellow
Optional Equipment
Air Inlet System
- Air inlet adapter
- Vertical support bracket
- Air cleaner louver assembly
- Boost control valve
- Soot filter
- Heavy duty air cleaner
Cooling System
- Auxiliary water pump
- Heat exchanger for single circuit
- Expansion tank
- Cooling system aids
- Heating aids
Exhaust System
- Flexible exhaust Fittings
- Weld flange and related hardware
Fuel System
- Duplex primary fuel strainer
- Fuel system connections
- Fuel priming pump
Generator System
- Winding temperature detectors
- Anti-condensation space heaters
- 3 Phase, Six Leads, WYE
- Class F insulation
- Busbar connections
Governor System
- Electronic/actuators
- EGB actuator
- Digital programmers
- Battery backup/power supply
- 230 UA
- 723 Plus
Lube System
- Oil pan drain valve
- Lube ANSI Adapter (Emergency connection)
Mounting System
- Spring type vibration isolators
- Vertically Restrained
- Non-vertically Restrained
- Isolator
Starting / Charging System
- Compressed air flex hose
- Turbine type air starters
- Pressure reducing valve
- Redundant air starters
General:
- Custom paint colors
{Promo Placeholder}