C9 Generator Set
Description
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Manufacturer: CAT
Brochures & Links
Specifications
Download Specification Sheets
- C9 60 Hz, 200 ekW, Tier III Non-Road Emissions Compliant Spec Sheet
- C9 60 Hz, 250 ekW, Tier III Non-Road Emissions Compliant Spec Sheet
- C9 60 Hz, 300 ekW, Tier III Non-Road Emissions Compliant Spec Sheet
| Standby Rating | 200/250/300 ekW |
|---|---|
| Prime Power Rating | 180/225/275 ekW |
| Emissions/Fuel Strategy | U.S. EPA Tier 3 Certified |
| Voltage | 220 to 480 Volts |
| Frequency | 60 Hz |
| Speed | 1800 rpm |
| Duty Cycle | Standby, Prime |
| Engine Model | C9 ATAAC, I-6, 4-Stroke Water-Cooled Diesel |
|---|---|
| Bore | 4.41 in112 mm |
| Stroke | 5.87 in149 mm |
| Displacement | 537.01 in³8.8 l |
| Compression Ratio | 16.1:1 |
| Aspiration | Air to Air Aftercooled |
| Fuel System | Hydraulic electronic unit injection |
| Governor Type | Adem™A4 |
| Length - Maximum | 157 in3988 mm |
|---|---|
| Width - Maximum | 47.5 in1207 mm |
| Height - Maximum | 73.5 in1867 mm |
Key Features
Cat Generator Set Package
- Cat generator set packages have been fully prototype tested
- Accepts 100% block load in one step and meets NFPA 110 loading requirements
- Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
- Reliable, rugged, durable design
- Field-proven in thousands of applications worldwide
- Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator
- Superior motor starting capability minimizes need for oversizing alternator
- Designed to match performance and output characteristics of Cat diesel engines
- Robust Class H insulation
GCCP Control Panel
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirement
- Expansion modules and site-specific programming for specific customer requirements
Cooling System
- Designed to operate in standard ambient temperatures up to 50°C (122°F)
- Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
- Designed to meet applicable global standards including ISO 8528, ISO 3046 and IEC 60034-1, with CSA, UL2200, IBC, NEMA and NFPA conformity available depending on configuration and market.
One Safe Source
- Components used in the generator set are selected based on seamless design integration to provide the optimum performance
- The generator set is fully assembled at a Caterpillar facility following our quality guidelines
- Each generator set package is tested before leaving the Caterpillar facility
- Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Equipment
Standard Equipment
Air Inlet System
- Air cleaner, light duty with disposable paper filter
Exhaust System
- Exhaust manifold - dry
- Stainless steel exhaust flex, gaskets, rain cap & SAE exhaust flange for customer use - shipped loose
Control Panels
- GCCP 1.2
Cooling System
- Caterpillar extended life coolant
- Fan drive, battery charging alternator drive
- Coolant drain line with valve
- Radiator and cooling fan with guard
Fuel System
- Narrow skid base
- Fuel cooler
- Primary fuel filter w/integral water separator and secondary filter
- Integral tank base
Generators and Generator Attachments
- Mandatory option circuit breaker, IEC, 3 pole mounted in power centre
- Cold weather bundle
- Current transformers
- Segregated low voltage (AC/DC) wiring panel
- Insulation Class H and temperature rise
- Power centre, IP22
- Automatics voltage regulator
Governing System
- Cat electronic governor (ADEM A4)
Mounting System
- Captive linear vibration isolators between base and engine-generator
- Includes lifting provisions and termination points for coolant and lube oil drain lines
Starting / Charging System
- Standard / Oversized batteries
General
- Engine and alternator re-paint, Caterpillar yellow
Lube System
- Oil cooler
- Oil drain valves
- Fumes disposal, piped to front of radiator
- Lubricating oil
- Oil filter and dipstick
- Oil drain lines with valve; piped to edge of base
Telematics
- Cat® Product Link™ PL444 cellular
Optional Equipment
Certifications
- IBC / HCAI
- Global Certification for CIS
Air inlet system
- Single element air cleaner
Circuit breakers
- Single / Dual / Third
Control Panels
- Load center / GFCI receptacle / I/O expansion module
- GCCP 1.5
Cooling System
- Radiator duct flange
- Low coolant temperature alarm
Enclosures
- Sound attenuated Level 1 / Level 2 (Steel / Aluminium)
- Weather protective
Exhaust System
- 5 - 6 inch flange adaptor
- 6 inch flange
- Mufflers - End in/end out; 10 dBA or 25 dBA attenuation
- 5 and 6 inch elbow kits
Fuel System
- Sub base tanks
- Integral dual wall fuel tank base
Generators and Attachments
- Permanent magnet excitation (PMG) generator
- Oversize, AREP, CIP generators
Starting / Charging System
- Jacket water heater
- 10A Battery charger
- Battery disconnet switch