Specifications

Standby Rating 600 ekW
Frequency 60 Hz
Emissions/Fuel Strategy U.S. EPA Tier 2 Certified
Voltage 480 to 600 Volts
Speed 1800 rpm
Duty Cycle Standby
Engine Model Cat® C18 In-line 6, 4-cycle Diesel
Bore 5.7 in145 mm
Stroke 7.2 in183 mm
Displacement 1106 in³18.1 l
Compression Ratio 14.5:1
Aspiration Turbocharged Air-to-Air Aftercooled
Fuel System MEUI
Governor Type ADEM™A4
Length - Maximum 196.1 in4980 mm
Width - Maximum 73.4 in1865 mm
Height - Minimum 79.1 in2009 mm
Height - Maximum 100.9 in2563 mm
Dry Weight - Genset (minimum) 8959.6 lb4064 kg
Dry Weight - Genset (maximum) 11647 lb5283 kg

Key Features

Cat Generator Set Package

        
  • Cat generator set packages have been fully prototype tested
  •     
  • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

SR500 Alternator

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

GCCP 1.2 Control Panel

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements

Cooling System

  • Designed to operate in standard ambient temperatures up to104°F (40°C)
  • Contact your Cat Dealer for specific ambient and altitude capabilities

Certifications

  • UL 2200 Listed
  • ULC Certification Available

One Safe Source

  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

Worldwide Product Support

  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Equipment

Standard Equipment

Air Inlet System

  • Air cleaner - Non canister, disposable

Control Panel

  • GCCP 1.2

Bases, Mounting & Fuel Tanks

  • Wide Base - Skid

Cooling System

  • Radiator sight gauge
  • Coolant drain valve
  • Jacket water pump, gear driven, centrifugal
  • Blower fan and fan drive with guards
  • Radiator, package mounted

Fuel System

  • Fuel cooler
  • Primary fuel filter w/integral water separator and secondary filter, spin on
  • Engine fuel transfer pump
  • Fuel priming pump

Generators and Generator Attachments

  • Voltage regulator (single phase sensing)

Governing System

  • Cat electronic governor (ADEM A4)

Lube System

  • Oil filler and dipstick
  • Shallow oil pan
  • Oil filter, spin on
  • Oil cooler
  • Lubricating oil, CK-4 (10W-30)
  • Oil drain with valve
  • Fumes disposal to front of radiator

Mounting System

  • Includes lifting provisions and termination points for coolant and lube oil drain lines
  • Captive linear vibration isolators between base and engine-generator

Protection

  • Safety shutoff - High water temperature
  • Safety shutoff - Overspeed
  • Safety shutoff - Low oil pressure

Starting/Charging System

  • 24V, 45 Amp Charging alternator
  • 24-volt electric starting motor

General

  • Vibration damper
  • Lifting eyes

Optional Equipment

Bases, Mounting & Fuel Tanks

  • Integral tank base, 24 hours, UL142
  • 5 Gallon Spill Containment
  • Overfill prevention valve
  • Fuel tank pill pipe & lockable cap

Circuit breaker

  • Single/ Multi manual LSI

Control System

  • 20A GFCI (Ground Fault Circuit Interrupter)
  • Ground fault relay
  • 16 -light NFPA 99/110 Annunciator
  • Twist release, Red button emergency stop
  • 100A Load center
  • Product link remote monitoring hardware
  • Remote E-Stop button
  • Discrete I/O module
  • Annunciators box
  • Local annunciator

Exhaust System

  • 8" Muffler - 25 dBA attenuation
  • Flexible exhaust connection
  • Manifold and turbocharger guards

Generator

  • Space heater
  • Permanent magnet excitation (PMG) generator

Starting System

  • Jacket water heater

General

  • Extended Service Coverage
  • Generator test report
  • CSA Certification
  • UL2200 Certification

Enclosures

  • E-Stop
  • Sound attenuated Level 2 enclosure (White)
  • AC & DC Source lights
  • Sound attenuated enclosure

Cooling System

  • Coolant heater
  • Stone guards
  • Jacket water heater with pump

Base / Fuel Tank

  • Audio & visual fuel alarm

Starting and Charging

  • Oversize battery set
  • Standard battery set
  • 5 Amp Battery charger
  • Battery disconnect switch

Certifications

  • CSA 22.2
  • UL2200 Listed
  • IBC Seismic

Lube System

  • Manual sump pump